Найти Non-blocking Pipe Sewage Pump, Single-suction Single-stage Centrifugal Pump, GW Type Non-blocking Pipe Sewage Pump на Промышленность Directory, надежный производитель / поставщик / завод из Китая

Корзина запроса (0)

GWP+stainless+steel+pipe+sewage+pump

Вид оплаты: L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,FCA,CPT
Количество минимального заказа: 1 Set/Sets
Срок поставки: 15 дней

Базовая информация

Модель: BODA-119

Описание продукта

%3Cp+class%3D%22p0%22+style%3D%22font-family%3AVerdana%2C+Arial%2C+Helvetica%2C+sans-serif%3Bcolor%3A%23505050%3B%22%3E+%3Cimg+src%3D%22%25oss_domain%25product%2F87%2Fbc%2F4d%2Fe140cf4b98acdaf984f90ee46f.jpg%22+alt%3D%22%22+%2F%3E+%3C%2Fp%3E+%3Cp+class%3D%22p0%22+style%3D%22font-family%3AVerdana%2C+Arial%2C+Helvetica%2C+sans-serif%3Bcolor%3A%23505050%3B%22%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3EGW+type+non-blocking+pipe+sewage+pump+product+features%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E1.+The+pump+is+a+vertical+single-suction+single-stage+centrifugal+pump.+The+center+line+of+the+inlet+and+outlet+is+on+the+same+horizontal+line.+The+inlet+and+outlet+flanges+are+the+same.+Therefore%2C+the+installation+and+disassembly+are+very+convenient.+The+floor+space+is+small+and+can+be+installed+in+the+pipeline+like+a+valve.+Location.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E2.+The+pump+and+the+motor+are+directly+coaxial+with+each+other.+It+is+a+mechatronic+product+with+compact+structure+and+stable+performance.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E3.+The+large-flow+anti-blocking+hydraulic+component+design+greatly+improves+the+dirt+passing+ability%2C+and+can+effectively+pass+5+times+of+the+fiber+diameter+of+the+pump+and+the+solid+particles+with+a+diameter+of+about+50%25+of+the+pump+diameter.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E4.+The+design+is+reasonable%2C+the+matching+motor+is+reasonable%2C+the+efficiency+is+high%2C+and+the+energy+saving+effect+is+remarkable.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E5.+The+mechanical+seal+adopts+hard+wear-resistant+tungsten+carbide%2C+which+has+the+characteristics+of+durability+and+wear+resistance%2C+which+can+make+the+pump+run+safely+for+more+than+8000+hours.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E6.+Advanced+hydraulic+performance%2C+high+efficiency+and+low+running+noise.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E7.+Add+a+protective+cover+to+the+fan+blade+end+of+the+motor.+The+whole+machine+can+be+placed+outdoors%2C+without+the+need+of+a+machine+room%2C+which+can+save+a+lot+of+capital+construction+costs.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E8.+Use+within+the+range+of+the+lift+to+ensure+that+the+motor+is+not+overloaded.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3EGW+type+non-blocking+pipe+sewage+pump+product+use%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E1.+The+discharge+of+serious+polluted+wastewater+from+the+factory+business.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E2.+Drainage+system+of+urban+sewage+treatment+plant.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E3.+Sewage+drainage+station+in+residential+area.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E5.+Sewage+discharge+from+hospitals+and+hotels.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E6%2C+municipal+engineering%2C+construction+sites.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E7.+Exploration+and+mine+supporting+machine.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E8.+Farmland+irrigation+in+rural+biogas+digesters.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E9.+The+water+supply+device+of+the+waterworks.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3EGW+type+non-blocking+pipe+sewage+pump+use+conditions%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E1.+The+medium+temperature+does+not+exceed+%2B40+%C2%B0C%2C+intermittent+use+%28length+not+exceeding+5+minutes%29+is+%2B70+%C2%B0C%2C+the+severity+is+1.0-1.3+kg%2Fdm3%2C+and+the+pH+value+is+in+the+range+of+5-9.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E2.+The+pump+without+internal+self-flow+circulating+cooling+system%2C+the+motor+part+does+not+exceed+1%2F2+of+the+liquid+level.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E3.+Under+normal+circumstances%2C+the+pump+must+be+used+within+the+range+of+the+lift+to+ensure+that+the+motor+is+not+overloaded.+If+it+is+to+be+applied+within+the+full+lift+range%2C+it+should+be+separately+indicated+at+the+time+of+ordering+for+the+manufacturer+to+manufacture.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E4.+The+motor+current+must+not+exceed+the+rated+current+of+the+motor+during+operation.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3EPreparation+and+operation+of+GW+type+non-blocking+pipeline+sewage+pump+before+starting%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E1.+First+check+if+the+external+fasteners+are+loose+during+transport.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E2.+Check+that+the+power+supply+voltage+meets+the+motor+nameplate+requirements.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E3.+Turn+on+the+power+and+try+to+turn+it.+See+if+the+impeller+is+turned+according+to+the+direction+indicated+on+the+pump.+If+the+direction+is+reversed%2C+adjust+any+two-phase+line+in+the+cable.+The+time+for+trial+rotation+should+not+be+too+long%2C+so+as+not+to+burn+the+seal.+.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E4.+Install+the+pump+and+turn+it+on.+It+is+good+to+install+the+pump+foot+screw.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3EGW+type+non-blocking+pipeline+sewage+pump+failure+and+elimination%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E1.+Before+using+the+pump%2C+check+the+insulation+resistance+of+the+motor+winding+to+the+casing.+If+it+is+less+than+0.5+megohm%2C+just+dry+the+stator+and+use+it+until+the+insulation+resistance+is+increased.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E2.+If+the+gap+between+the+impeller+and+the+oil+seal+at+the+inlet+of+the+pump+body+exceeds+2mm%2C+the+wear-resistant+oil+seal+should+be+replaced.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E3.+When+there+is+water+leakage+in+the+pump+seal%2C+the+seal+should+be+replaced+in+time.+When+replacing%2C+seal+the+static+seal+first%2C+then+install+the+dynamic+seal+on+the+shaft.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E4.+When+replacing+the+impeller%2C+pull+out+with+the+tensioner%2C+and+do+not+hit+it+with+a+hammer+to+avoid+damage+to+the+shaft.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3ECommon+cause+of+failure%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E1.+No+water%2C+the+liquid+is+too+heavy+and+the+particle+size+is+too+high%3B+the+liquid+flow+channel+is+blocked%3B+the+impeller+is+turned+wrong%3B+the+bar+is+pumped+into+the+impeller%3B+the+pipe+outlet+height+exceeds+the+rated+head+height.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E2.+Insufficient+flow+and+low+lift.+Low+voltage%2C+impeller+steering+error+or+wear-resistant+seal+wear%3B+liquid+heavy+particle+size+is+too+high.%3C%2Fspan%3E%3Cbr+%2F%3E+%3Cbr+%2F%3E+%3Cspan+style%3D%22color%3A%23333333%3Bfont-family%3ATimes+New+Roman+%2C+Times%3Bfont-size%3Amedium%3Bline-height%3A24px%3Bbackground-color%3A%23FFFFFF%3B%22%3E3.+The+insulation+resistance+is+low%2C+the+surrounding+environment+is+wet%2C+and+the+mechanical+seal+is+seriously+leaking.%3C%2Fspan%3E+%3C%2Fp%3E

Группа Продуктов : Насос сточных вод канализации